กระจกตาแมว แบบมีแถบแสดงตรวจจับความชื้น 3/8" ODS Solder. (เชื่อมบัคกรี) Product Details Connections Ø ODS [in.] 3/8" PS [bar] 50 MWP [psi] (1) 500 TS [°C] min. -40 TS [°C] max. +120"

Brand : Castel
Model : 3940/3
Product type : Sight glass solder
Size : inlet x outlet = 3/8" ODS X 3/8" ODS solder.
Details : Moisture Indicator 3/8" ODS use with the following ASHRAE 34:2019
refrigerants, Class A1: HCFC (R22) HFC (R134a, R404A, R407C, R410A, R507)
HFO (R1234ze) HFO + HFC (R448A, R449A, R450A, R452A, R513A, R515A, R515B)
Product Details Connections Ø ODS [in.] 3/8" PS [bar] 50 MWP [psi] (1) 500
TS [°C] min. -40 TS [°C] max. +120
Safety devices 1/4" NPT x 3/8" SAE Model 3060/23
กระจกตาแมว แบบมีแถบแสดงตรวจจับความชื้น 3/4" SAE.Flare. (ขันเกลียว) Product Details Connections Ø SAE.Flare. [in.] 3/4" PS [bar]50MWP [psi] (1)500TS [°C] min. -40 TS [°C] max. +120"
Stop valves by diaphragm Diaphragm Valve 5/8" ODS Product use with the following ASHRAE 34:2019 refrigerants, Class A1: HCFC (R22) HFC (R134a, R404A, R407C, R410A, R507) HFO (R1234ze) HFO + HFC (R448A, R449A, R450A, R452A, R513A, R515A, R515B) Product Details Connections ODS Ø [in.] 5/8" Kv [m³/h] 1,80 PS [bar] 28 TS [°C] min. -35 TS [°C] max. +90"
Connections 1-3/8”ODS.(1-5/8"ODM) ,Ts= -35 to +150 C ,Ps=45 bar ,Kv=15.0 m3/h
วาล์วเปิด-ปิดด้วยมือหมุน / Stop valves by diaphragm Diaphragm Valve 5/8"Flare inlet and outlet. Valve use with the following ASHRAE 34:2019 refrigerants, Class A1: HCFC (R22) HFC (R134a, R404A, R407C, R410A, R507) HFO (R1234ze) HFO + HFC (R448A, R449A, R450A, R452A, R513A, R515A, R515B) Connections SAE Flare 5/8" Kv [m³/h] 1,80 PS [bar] 28 TS [°C] min.-35 TS [°C] max. +90
solenoid valve 5/8"ODS Model 1078/5
Flang shut off Valve, Outlet Flare Jointed 5/8" SAE. with in Access Valve Flare 1/4" SAE.
solenoid valve 1/2"SAE Diaphragm, specifically used with HCFC ,HFC,HFO,water,compressed air,gas,oil,
The gauge mounting valves,which use the following refrigerant fluids: R22 , R134a, R404A, R407C, R410A; R507 proper to the Group II (as defined in Article 9, Section 2.2 of Directive 97/23/EC and referred to in Directive 67/548/EEC). Connections SAE. Flare 1/4" inlet and NPT.1/8" to gauge, Depth installing 17 mm. ,,Ts= -60 to +130 C ,Ps=45 bar ,that have to a little flange for fixing the valve to the control panel - a SAE-Flare connection for joining it to the copper tube - an NPT (type 8320) or a swivel SAE Flare (8321) connection for mounting the gauge"
solenoid valve 5/8"SAE Diaphragm, specifically used with HCFC ,HFC,HFO,water,compressed air,gas,oil, MOPD.=0.05 to 21 bar ,Kv=2.61m3/h ,Ps45 bar ,Ts= -35 to +105 C
Safety devices 3/8" NPT x 1/2" SAE Model 3060/34